GRID20/20 - Distribution Transformer Monitoring System

GRID20/20 - Distribution Transformer Monitoring System
larger imageMove mouse over the image to magnify

Grid20/20 US designed and manufactured OptaNODE Distribution Transformer Monitor (DTM) leverages the strategic value of transformers within the distribution grid into Smart Transformers. The OptaNODE DTM and PDTM devices grant utilities a clear vision of the LV network and distribution transformer health.

Grid20/20 pride the OptaNODE solution on ease and speed of installation, accuracy of patented outdoor rated and UV stable current sensors as well as compactness and robustness of design. Voltage, Current, Demand and Temperature feedback is aggregated and sent wirelessly (3G/RF-MESH) to Grid2020 servers for real-time analytics and reporting.

The HESS (Head End Server System) hosted by Grid20/20 in a leading US Datacentre provides storage of the collected data plus analytics and reporting designed specifically around the asset health of distribution transformers and LV network. Overloaded and underutilized transformers are detected instantly and current/voltage issues are concisely identified.

Grid20/20 provides bi-directional energy feedback on transformers connected to Distributed Generation (wind/solar) ensuring distribution transformers are still operating within their design constraints.  

The ethos surrounding the OptaNODE design is to keep the unit cost low, allowing for greater network deployment which collectively provides a clearer picture of the LV network as a whole. The OptaNODE units are self-contained and maintenance free, designed for permanent installation both pole-top and pad-mount.

Optional extras: include SCADA integration, Energy balancing (theft detection), RF-Mesh compatibility, outage notification.

KEY ADVANTAGES
  • Self-contained/Maintenance Free unit: Metering, Sensing, and Communications fully integrated.
  • High accuracy of monitored transformer parameters within all ranges of operation
  • Speed and simplicity of installation. No on-site calibration.
  • AMI, SCADA, MDM, 3rd party platforms integration via DNP3, FTP, Web-services and MultiSpeak Interfaces.
  • Flexibility to operate in diverse networks: multiple communications options available.
  • Reduced complexity – all backhaul infrastructure is operated by Grid20/20 meaning no on-site expertise required.
  • Web Based, secure graphical user interface available anywhere in the world. 
Data Points (per phase where applicable)
Energy (0.5% ANSI Class)
Forward & Reverse
[kWhr] Active Energy
[kVAhr] Apparent Energy
[kVARhr]* Reactive Energy
Power Factor*
RMS Voltage [V] Instantaneous, Maximum & Minimum per interval
RMS Current [A] Instantaneous, Maximum & Minimum per interval
Line Cycle Period [Seconds](1/Hz)
Temperature (by proximity) [°C]
Outage Notification Last Gasp available PDTM Q1 2017

BROCHURE
Grid20-20 cover
Cat No. Phases Voltage Communication Outdoor Rated Maximum Current Qty
DTM-GP-GSM
1
216-264 VAC
3G (GSM)
Yes
1000A
DTM-GP-GS
1
216-264 VAC
RF-MESH
Yes
1000A
DTM-FX-GSM
1
216-264 VAC
3G (GSM)
No
1000A
DTM-FX-GS
1
216-264 VAC
RF-MESH
No
1000A
PTDM-GP-GSM
3
100-600 VAC
3G (GSM)
Yes
1000A
PTDM-GP-GS
3
100-600 VAC
RF-MESH
Yes
1000A
PTDM-FX-GSM
3
100-600 VAC
3G (GSM)
No
1000A
PTDM-FX-GS
3
100-600 VAC
RF-MESH
No
1000A

You might also be interested in ...

$0.00
excl GST
Wire Grips
$0.00
excl GST

Signup for Juice & Email Specials

TransNet Juice is a regular industry publication that delivers our latest news, products and special offers to industry members.  Our email specials are available for purchase through all good electrical wholesalers.

btn signup
 

Contact us

phn1+64 9 274 3340 (NZ)
building+64 9 274 5490
mail   sales@transnet.co.nz

mail   78 Cryers Road
         East Tamaki
         Auckland    
Facebook-977 
Follow us on Facebook