HVLB-SICO for Cable Sheath Bonding with Single Core Cable

(0)No Reviews yet

HVLB-SICO for Cable S

TE Connectivity’s (TE) high voltage link box HVLB provides a sealed and dry environment for high voltage cable sheath earthing connection. It reduces voltages and circulating currents.


TE offers three types of link boxes with different number of entries to bond the cable sheath to the ground: HVLB-SICO-SLV, HVLB-SICO-GND and HVLB-SICO-CRO.


Within the HVLB-SICO-SVL link box, the cable sheath is earthed via a Sheath Voltage Limiter (SVL). The HVLB-SICO-GND link box is used to earth the cable sheath direct to the ground without a SVL. Within the HVLB-SICO-CRO link box the cable sheaths are crossbonded.


To get an easy access to the cable sheath for inspections, TE developed a reliable gasket-lid-system, which is tighter against water and dust. The lid system is equipped with a proof device for padlocks to prevent unauthorized access.


A well-arranged configuration ensures a higher reliability. Homogeneous distances between the electrical path, trustworthy electrical connections and a special developed short-circuit-yoke allow a better impulse-voltage and short-circuit withstand. For safety in an unexpected case, our box is tested to absorb the power of an internal arc with 25 kA for 0.1 sec.


Features

  • Impulse withstand: 65 kV
  • Short circuit current: 63 kA/1 s
  • Internal power arc: 25 kA/0.1 s
  • Tight against water and dust according to protection class IP68
  • Gland sealing with WCSM heat shrinking tube
  • Sequential serial number for each link box
# of Cable EntriesSize of the SVLHousing Earthing TypeCable Port SpecificationModification
Basic Description1 kV: CPA-01-017
2 kV: CPA-02
3 kV: CPA-03-017
4 kV: CPA-04
5 kV: CPA-05
6 kV: CPA-06-017
7 kV: CPA-07
8 kV: CPA-08
sep = separately
col = collective
S1 = 0 - 95 mm²
S2 = 95 - 240 mm²
S3 = 240 - 400 mm²
C8 = 500 mm²
S = shear bolt
C = crimp
M01 (standard)
Mxx (customer specific)
DIRECT GROUNDING
HVLB-SICO-GND1E
3E
6E
./.sep / colS1 / S2 / S3 / C8M01 / Mxx
VIA SHEATH VOLTAGE LIMITER (SVL)
HVLB-SICO-SVL1E
3E
1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 kVsep / colS1 / S2 / S3 / C8M01 / Mxx
CROSS-BONDING
HVLB-SICO-CROOUT1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 kVsep / colS1 / S2 / S3 / C8M01 / Mxx
CREATION OF PRODUCT DESCRIPTION SHOWN BY THE EXAMPLE OF HVLB-SICO-SVL-1E-6KV-COL-S2-M01
HVLB-SICO-SVL1E6 kVcolS2M01

EL5256-000
Direct Grounding, 3 Cable Entries, No SVL, Housing is separately earthed, Cable Port Range 95-240mm2 with Shearbolt Connection
EN1493-000
Direct Grounding, 3 Cable Entries, No SVL, Housing is separately earthed, Cable Port Range 0-95mm2 with Shearbolt Connection
EN2258-000
Direct Grounding, 6 Cable Entries, No SVL, Housing is separately earthed, Cable Port Range 95-240mm2 with Shearbolt Connection
EN5790-000
Cross Bonding, Out only, SVL size 3kV CPA-03-017, Housing is separately earthed, Cable Port Range 95-240mm2 with Shearbolt Connection

Cat No.

Description

Qty

Price

Ratings & Reviews

No reviews available

Be the first to Write a Review